DCP007 Complete Color
The Kemtrak DCP007 is an industrial UV-VIS-NIR fiber optic photometer designed to accurately measure the concentration of light absorbing substances. The Kemtrak DCP007 uses a combination of long life,solid state LED lamps with fiber optics that provide a measurement with very high precision. Thanks to a proprietary dual wavelength four channel measurement technique, high concentration to ppm trace analysis is no problem. The primary “absorbing” wavelength measures any changes in the process medium, while the second reference wavelength, which is not absorbed by the process medium,compensates for turbidity and/or fouling of the optical windows. Since optic fibers are used to pipe light to the measurement point and back, the measurement cell contains no electronics, moving parts or sources of heat that result in condensation on the optical surfaces. Standard measurement cells are machined in sanitary grade stainless steel with sapphire glass.
Product Description
• Real time in-line measurement
• Color & concentration: 280 – 2 000nm
• Zero maintenance
• High performance long life LED lamps
• Fiber optics - no condensation intrinsically safe (ATEX)
• Extensive range of industrial sensor designs
• Alarm signals for data and system failures
• Integrated PID controller
Main Features
Specification
supertronsensing096041.gif
 Housing  Glass-fibre reinforced polyester & polyester front panel
 Captive lid screws & wall mounting brackets stainless steel
 220 x 120 x 90 mm (8.66 x 4.72 x 3.54 inch) L x W x D
 IP 65 / EN 60529  
 Display    16 x 2 alphanumeric dot matrix LCD display
 LED background illuminated
 Display update: 0.5 seconds
 Display units: g/L, ppm, %, M, AU. User configurable.
 LED 1 (green): power on
 LED 2 (red): alarm
 LED 3 (red): clean 
 Operation   4 push buttons
 Data Logger   • 6 900 data points (timestamp, average, max. & min.) , ring buffer
 • Configurable log time interval 1s to 24hr  
 Event Logger  
 • 10 000 events
 • Alarms, zeroing, cleaning, calibration & system events
   (power, system failures, high/low system temperature) 
 Photometric
 Range  
 At 500nm, 10mm OPL: 0.000 - 3.000 AU 
 Photometric
 Accuracy 
 At 1AU (NIST 930D filter): ±0.001 AU
 At 2AU (NIST 1930D filter): ±0.005 AU  
 Photometric
 Noise
 At 1AU, 25°C, 500nm: ±0.0001 AU
 Linearity
 ± 0.5% of respective measuring range
 Remote Input  1 x Digital input (potential free contact) for:
 • Auto clean
 • Zero
 • Hold output
 mA Output  1 x 0/4 - 20 mA galvanically isolated
 Accuracy: <0.2%
 Resolution: < 0.05%
 Load: 0 - 400 Ohm
 Relay Outputs  2 x 0.5A 240VAC User configurable (alarm, PID, system fault)
 1 x 0.5A 240VAC Automatic cleaning control
 PTC resistor fuses in series with the relays
 LED status indicators flash when relays are active
 Fail-Safe  Relay output & 0/4-20mA value
 Operating
 Conditions
 Ambient temperature: -10°C to +50°C (14°F to 122°F)
 Transport: -20°C to +70°C (-4°F to 158°F) 
 Power
 Supply
 115/230V AC selectable, 50-60Hz, 1A
 Power
 Consumption
 25 VA (max.)
 Certificates
 ISO 9001:2000, CE, ATEX I I 2 GD EExd-IIB-T5 I (option)
 Manifolds
 Standard designs include DIN Flange (DIN 2633),
 Tri-Clamp® (ISO 2852 & DIN 32676),
 Sanitary Thread SC (DIN 11851),
 Straight Pipe Thread (DIN ISO 228 BSP).
 Line size up to DN100.
 Materials
 Standard material stainless steel EN 1.4435 / 316L.
 Other materials include Titanium, Hastelloy C-276, PEEK,
 TFMC (TFM 25% Carbon), PCTFE, PVC-C, PVDF
 Operating
 Conditions
 Ambient & process temperatures up to 200°C (392°F)
 Process pressure from 10 mbar to 100 bar
 Operating conditions subject to material and design in use 
 Protection  IP66 / EN 60529, ATEX (option)
& Concentration Control
supertronsensing096039.jpg
How it works
Measuring Principle
The Kemtrak DCP007 color & concentration analyzer consists of three components:

1. Control Unit. The control unit contains all electronics including light source and detectors.
2. Flow Cell. In-line (flow through) measurement cell.
3. Fibre Optics. Industrial grade fibre optic assembly connects the control unit to the flow-cell.
The Kemtrak DCP007 photometer measures at two wavelengths. A primary "absorbing" wavelength is used to measure the substance being monitored while a "non absorbing" reference wavelength is used to compensate for turbidity, air bubbles and/or fouling.
Fiber optics are used to shine a precisely focused light beam through the process medium and back to a silicon photo-detector. A second photo-detector is used directly on the lamps to compensate for temperature effects and aging. The resulting measurements are very accurate with low drift and long-term calibration stability.

The attenuation of the transmitted light beam caused by light absorbing substances in the process medium is mathematically described by the Beer-Lambert law.

Applying the Beer-Lambert law (below), the concentration of the sample can be calculated.
where:
    A = absorbance (= - log transmittance)
    e = molar absorptivity coefficient
    l = optical path length
    c = concentration of absorbing species

 
 
The Kemtrak DCP007 photometer is ideally suited for industrial environments where simplicity, stability and zero maintenance is vital.
supertronsensing096036.gif supertronsensing096035.gif supertronsensing096034.gif supertronsensing096033.gif supertronsensing096032.gif supertronsensing096030.gif supertronsensing096028.gif supertronsensing096026.gif supertronsensing096024.gif supertronsensing096022.gif supertronsensing096020.gif supertronsensing096017.gif supertronsensing096015.gif supertronsensing096014.gif supertronsensing096013.gif supertronsensing096009.gif supertronsensing096008.gif supertronsensing096007.gif supertronsensing096005.gif supertronsensing096002.gif supertronsensing096001.gif