Main Features
• Range of application (temperature): -40…85 °C
• Current or voltage output signal
• Optional: directly connected Pt100 sensor
• UART & service interface to PCB
Specification
MP102H and MP402H series probes provide truly class leading accuracy and stability. Based on the HygroClip HC2-S3 probe, they provide linear voltage or current outputs for secure transmission over extended cable lengths. An RS485 interface is available on request. With direct 4 -wire Pt100 temperature measurement available in the same probe assembly as the new AirChip3000 technology, this ultimate meteo probe combination offers outstanding performance within a single shield installation.
Supply voltage :
Range of application electronics :
5…24 VDC (MP102H)
15…24 VDCV ,min = 10 V +(0.02 x load*)
(MP402H)
-40…85 °C
Current consumption :
>1 k ohm(MP102H)
<500 ohm(MP402H)
* Load (in ohm) :
<±1 % rh/year
Long term stability (humidity sensor) :
Humidity sensor :
Humidity measurement range :
<6 mA(MP102H)
<50 mA(MP402H)
Voltage(MP102H)
Current(MP402H)
Output signal type:
Freely scalable
Temperature measurement range :
0…100 % rh
Same as HC2-S3 probe
Same as HC2-S3 probe
Accuracy (humidity) :
N/A, HC2-S3 probe
Temperature sensor :
N/A, HC2-S3 probe
Reproducibility :
Same as HC2-S3 probe
Accuracy (temperature) :
HygroMet Meteorological Probes
MP102H/402H
Product Description
Delivery: