VPFlowMate Probe
The VPFlowMate probe is an easy to install solution for compressed air and technical gases. The VPFlowMate probe can be installed in pipe sizes from 2 inches and up. The VPFlowMate can be connected directly to a PC and most analogue and industrial equipment. An optional integrated display is provided for direct read out of flow and total volume. Together with the VPFlowTerminal remote display, the VPFlowMate forms a plug and play solution for compressed air flow metering.
Product Description
Main Features
Specification
• Easy to install and easy to use
• Versatile: for various pipe diameters
• Reliable thanks to our patented thermabridge sensor technology
• Solid state (CMOS) thermabridge flow sensor
• Digital (RS232) output
• 4..20 mA Output
Software configurable
For the optimal flexibility, you can
adjust the installation conditions
with the VPSuite Software
Versatile outputs
RS232, 4..20 mA (linear), pulse: all standard available
Rugged, modular design
IP55 housing design Optional LCD display module Different probe lengths
Built-on display option
Features flow and totalizer read out
• Direct read out of flow
• Direct read out of total consumption
• Clear back-lit display
| Measurement |
|
|
Average measurement uncertainty
(ideal field conditions)
|
3% of measured value + 0.5% of span.
Please note that for
insertion probes, the field accuracy depends on installation
conditions.* |
| Reproducibility |
<
0.5% of measured value per year when used with clean
compressed air. |
| Ranges |
0..150 mn/ sec (mn is referenced to 0o
Celsius, 1013.25 mbar)
0...80 mn/ sec
0...20 mn/ sec |
| Zero cutoff point |
Depends on model; typically 1 to 2% of
full scale |
| Temperature range |
0..50 o C. ** |
| Pressure limit |
16 bar maximum pressure *** |
| Humidity range |
Up
to 95% Relative Humidity, non condensing |
| Gases |
Compressed Air, Nitrogen, non corrosive gasses |
| Mechanical |
|
| Connections |
Connected
with 0,5“ compression fitting |
| Dimensions |
See technical drawings |
| Protection type |
IP55. Not for outdoor use. |
| Housing
material |
Aluminium, painted |
| Wetted materials |
Epoxy, glass, stainless steel 316 |
| Corrosion resistance |
Highly
corrosive or acid environments should be avoided |
| Electrical |
|
| Outputs |
RS232, 4..20 mA, pulse |
| Power supply |
12..24
Volt DC +/- 10% Class II (CUL requirement)
ower consumption < 100 mA. Peak power at startup 500 mA |
| Connections |
Multi
pole connector |
| Approvals/ conformity |
|
| CE |
EN 61326-1 |
| CE |
EN 50082-1 |
| CUL |
14 AZ, Industrial Control
Equipment |
- NOTE: See technical guidelines for installation effects and ideal installation requirements.
** NOTE: The temperature error is typically less than 0.1% of reading per degree Celsius.
*** NOTE: The pressure error is typically 0.3% of full scale per bar deviation of the calibration pressure. The pressure error of the VPFlowMate® is specified for a range of +/- 3 bar around the calibration pressure. Ask for custom calibration when using the VPFlowMate® at atmospheric or low line pressure
Delivery: