VPFlowScope DeltaP
VPFlowScope is the first insertion mass flow meter that can measure in saturated air. Measuring directly behind a compressor or in a system without a dryer, flow measurements were a difficult and costly task. Now with the VPFlowScope deltaP you have a powerful tool!
The VPFlowScope deltaP gives read out on mass flow, pressure and temperature. The VPFlowScope deltaP is based on differential pressure principle. The design of the sensor-tip, combined with the water repellant layer, makes the VPFlowScope deltaP extremely resistant to pollution.
Compressor efficiency monitoring.
Near ISO 1217 compliant field testing of compressors.
High temperature and saturated air applications.
Product Description
Main Features
Specification
• All-in-one: The VPFlowScope measures mass flow, pressure and temperature simultaneously, making extra sensors and cables redundant.
• Proprietary design and repellent layer, make the VPFlowScope resistant to dirt and water drops.
• Easy to install: Just mount the VPFlowScope in the pipe, enter the pipe diameter and you can start measuring immediately.
• Solid state (CMOS) flow sensor
• Compatible with the VPFlowScope product family.
• Versatile: for various pipe sizes (2” and up).
Delivery:
| flow range |
20..200mn/sec* |
| rangeability |
1:10 |
| pressure range |
0..10 bar abs |
| temperature(sensor head) |
-40..+150
degC. Ice should be avoided! |
| humidity range |
100% condensing, mounted vertically |
| accuracy |
<2% reading over 1:10
range |
| outputs |
4..20mA, RS485 |
| probe length |
400 mm |
| probe diameter |
12.7 mm (0,5”) |
| installation diameter |
50...300
mm |
| mounting |
0.5 inch compression fitting |
| gases |
Compressed air, N2, other gases on request |
| data logger |
500.000
points |
* NOTE: Calibrated 20..120mn/sec